Thailand Medical Device Registration for Manufacturers Already Registered in Indonesia: What Carries Over and What Does Not

Thailand Medical Device Registration for Manufacturers Already Registered in Indonesia: What Carries Over and What Does Not

DeeMED Consulting
November 9, 2026

Contents

If your device already holds an izin edar from Indonesia’s Ministry of Health, you have done much of the work Thailand will ask for. Both countries build their device rules on the ASEAN Medical Device Directive (AMDD), both sort devices into four risk classes, and both have signed up to the same ASEAN dossier template. But a shared framework is not a shared approval. Thailand will not accept your Indonesian registration in place of its own, and the issues that most often delay a first Thai filing have little to do with the device itself.

This guide covers:

  • What you can reuse from your Indonesian file
  • What Thailand requires that Indonesia does not
  • Why the choice of Thai licence holder matters more than most manufacturers expect
  • Thai government fees by class, and a short checklist before you file

Indonesia and Thailand at a Glance

IndonesiaThailand
RegulatorMinistry of Health (the izin edar is issued by the Minister)Medical Devices Control Division (MDCD), Thai FDA, Ministry of Public Health
Risk classesClasses A to D (Permenkes 5/2026)Classes 1 to 4, aligned with AMDD Classes A to D
Who holds the registrationA licensed Indonesian distributor or importer appointed by the manufacturerA Thai importer or manufacturer with a Thai FDA establishment licence
Label languageBahasa IndonesiaThai for home-use devices; Thai or English for professional-use devices
Accepts the other country’s approvalNoNo

What Carries Over From Your Indonesian File

The science. Your clinical evidence, risk management file (typically to ISO 14971), verification and validation data and ISO 13485 certificate are the same kinds of evidence Thailand asks for. ISO 13485 is required in Thailand for Classes 2, 3 and 4. Class 1 devices follow Thai GMP guidelines instead.

The dossier structure. Thailand requires the ASEAN Common Submission Dossier Template (CSDT) for Classes 2 to 4, with its table of contents set out in Annex 4 of the ASEAN Medical Device Directive. If your Indonesian dossier follows the CSDT structure, much of it can be reused. Treat it as the starting point for the Thai file, not the finished Thai file.

The classification logic. Thailand numbers its classes 1 to 4, aligned with the AMDD letters A to D, so an Indonesian Class C device will often land in Thai Class 3. “Often” is the important word. Thailand classifies the device as it will be labelled and used in Thailand, and if the intended use or indications in the Thai application differ from the Indonesian ones, the class can differ too. Confirm the Thai class against our guide to Thai medical device classification before preparing anything. A file submitted under the wrong class is rejected, the fee is not refunded, and the application restarts under the correct class.

What Thailand Requires That Indonesia Does Not

A Thai licence holder

The Thai registration must be held by a Thai importer or manufacturer that holds an establishment licence from Thai FDA. Your Indonesian licence holder cannot hold it, and neither can you as the overseas manufacturer. You authorise the Thai holder with a Letter of Authorization, which is required for every class.

Thai-language documents and labels

Application forms are filed in Thai, and Thai FDA’s CSDT guidance expects some sections, such as the executive summary and device description, in English plus Thai. Labels follow the labelling notification B.E. 2568, in force since 20 June 2026: Thai for home-use devices, and Thai or English for devices used by healthcare professionals. Bahasa Indonesia labels do not meet either requirement. The labels must be in place before the device is sold, and in any case within 120 days of the day the inspection checkpoint releases the shipment.

A separate Thai review

The AMDD harmonises the rules but contains no operative mutual recognition between member states. What Thailand does have is a published list of foreign authorities whose device approvals Thai FDA accepts as the basis for a reliance review: Australia’s TGA, Health Canada, EU notified bodies, Japan’s Ministry of Health, Labour and Welfare, the US FDA, the World Health Organization’s IVD prequalification programme, Singapore’s HSA and, since an amendment signed on 6 October 2026, Malaysia’s Medical Device Authority (MDA). An approval from one of the first five must have been held for at least a year, and HSA and MDA approvals count only under their reliance programmes with Thai FDA. In every case, the intended use, indications, labelling, instructions for use and packaging in the Thai application must match what that authority approved.

Indonesia’s Ministry of Health is not on the list. Your izin edar still belongs in the Thai file as evidence of your device’s regulatory history, but it will not shorten the Thai review.

So check what else the device holds. If it also has an approval from an authority on the list, lead with that approval. The Malaysian route is the clearest example: since 1 May 2026, a Class 2, 3 or 4 device approved by MDA under the MDA and Thai FDA reliance programme can skip Thailand’s external expert evaluation, provided the CSDT dossier is complete.

Choosing Your Thai Licence Holder

Many manufacturers let their Thai distributor hold the registration. It is the fastest option on day one, and it can be the most expensive later. The registration belongs to the holder, not to you. To move it to a new holder, the new holder files its own application with a letter of consent from the current holder, and the old registration is cancelled once the new one is approved. If the distribution relationship ends badly, the distributor’s cooperation is what stands between you and your Thai market.

Before signing, ask who will hold the registration, what happens to it if the commercial relationship ends, and whether the holder will sign a letter of consent to transfer on request. An independent regulatory holder that does not distribute removes the conflict entirely.

Thai Government Fees by Class (Imported Devices)

Thai classRouteBase fee (THB)Expert review, if Thai FDA refers the file (THB)
Class 1Listing3,100Not applicable
Class 2Notification11,00038,000 (rarely called for)
Class 3Notification11,00038,000 (sometimes called for)
Class 4Licence21,00053,000 (often called for)

Thai FDA decides on expert review case by case, and when it applies, it is the largest single government cost. Establishment licensing and professional fees are separate. Review times vary with application complexity and MDCD workload, so plan with buffer rather than a fixed date.

A Checklist Before You File in Thailand

  1. Confirm the Thai class for the device as it will be labelled and used in Thailand.
  2. Choose your Thai licence holder and sign the Letter of Authorization.
  3. Run a gap check of your Indonesian dossier against Thai requirements, including the required sections and forms.
  4. Prepare Thai label artwork before the first shipment, not after it arrives.
  5. List every other approval the device holds, such as from the US FDA, an EU notified body, or Malaysia’s MDA, and check whether one qualifies for Thailand’s reliance list.
DeeMED Consulting
Article Contributor

DeeMED Consulting

A Bangkok-based regulatory consultancy that acts as Thai license holder, Local Authorized Representative and Importer of Record for foreign device manufacturers. DeeMED does not distribute products. This article is general information about Thai medical device regulation and is not legal advice for any specific product.

Product Registration Indonesia helps you get your product approved and on the market, from BPJPH, BPOM, to Kemenkes.

Inquiry Form

Our team is prepared to discuss your business needs and address any questions you may have. Fill out our inquiry form, and we’ll respond within one business day.

Contact Form
Submit with your company email for quicker response and priority handling.

Other ways to get in touch with us.

Related Article
Indonesia Hospital Tender Registration: Why Public Hospital Bids Require an Izin Edar You Do Not Yet Have
Class A, B, C, D: How Indonesian Medical Device Risk Classification Drives Everything Downstream
Registering High-Energy Therapeutic Equipment in Indonesia: Proton Therapy, Brachytherapy, and Linear Accelerators
Indonesia Hospital Tender Registration: Why Public Hospital Bids Require an Izin Edar You Do Not Yet Have
Class A, B, C, D: How Indonesian Medical Device Risk Classification Drives Everything Downstream
Indonesia Hospital Tender Registration: Why Public Hospital Bids Require an Izin Edar You Do Not Yet Have

Download via Email

Enter your email to get the document delivered to your inbox.

Documents lead form